ECONOFIX-10

TECHNICAL INFORMATION SHEET NO. 42

ECONOFIX-10  A Major advancement in fireside cleaning of combustion deposits"

ECONOFIX-1O

FIRE SIDE TREATMENT CHEMICAL

ECONOFIX-10 a complete fireside treatment for boilers. It may save Rs. 27,000/- per year for every tonne of steam, generated per hour by maintaining the fireside surfaces of boiler.

ECONOFIX-10 a chemical formulation for total fireside cleaning of combustion deposits, contains dispersants, combustion catalysts, oxidising chemicals and corrosion inhibitions.
ECONOFIX-10 is a free flowing powder, non toxic and safe to handle and is fed directly into furnace while boiler is in operation. ECONOFIX-10 offers following advantages.

ADVANTAGES OF ECONOFIX-10

Through C leaning of Fireside Surfaces.Improves Efficiency - Saves Fuel.
Improves Superheater Temperature.
Increases Metal Life of Boiler.
Increases Effective Steam Generation.
Reduces Soot Blowing Frequency & Soot Blowing
Steam Requirement
Increases Life of Refractory.
Minimises Down Time of Boiler.
Reduces Man Power (Cleaning) Cost
Increases Life of Superheater.
Reduces Frequency of Shutdown.
Pollution Control.
Clinker is Softened.
Inhibits Corrosion.
Cleans inaccessible Parts.
Provided on Line Cleaning of Boiler.
Lowers the Stack Temperature.
Soot thickness.

mmLoss in Conductivity percent0.8 1.6 3.2 4.89.5 26.2 45.3 69.0The effect of this reduced heat transfer is usually reflected in a loss of efficiency as can be observed from the higher stack tempratures generated by the boiler or heater. The reduction in conductivity can be related to reduction in efficiencies.

Sooting, clinker and other combustion deposits are common fireside occurrences in boiler and thermic

fluid heater installations. Such deposits have to be cleaned manually by brushing, scouring or by chemical action which leaves much to be desired. The cleaning is almost never perfect and cannot reach certain sections of the heating surface which have poor accessibility. The adhesive properties oi unburnt carbon results in the build-up oi incombustible solids and boiler effciency. The carbon acts as a thermal barrier reducing heat transfer on the heat transfer surfaces.

HOW ECONOFIX - 10 REACTS

When the chemicals enter the high temperature zone, they vapourise and deposit as a thin film on the

relatively cooler surfaces of the furnace. The combustion catalysts reduce the ignition temperature of the adhering carbon pemitting to burn at reduced temperatures. Oxidising agents provide the oombustion oxygen. This action exposes the bare metal of the heat exchanger. The corrosion inhibitors protect the metal from corrosion by acids produced during combustion and prevent scale formation due to metal oxidation.

BENEFITS OF ECONOFIX - 10

While traditional cleaning methods cause a sharp decrease in efficiency and increase in stack temperature between equipment at peak effciency shutdowns; ECONOFIX-10 maintains combustion continuously. Regular use of ECONOFIX-10 results in the complete removal of fireside deposits.

ECONOFIX- 10

* Improve heat transfer
* Increases efûciency by 2% to 5%
* Reduces manpower requirement of boiler cleaning
* Reduces downtime
* Increases boiler availability
* Extends the life of the heat exchanger

ECONOMICS OF ECONOFIX-10

OIL (78% eff.) COAL (60% eff.)
Annual fuel cost

Annual cost of ECONOFIX

Savings in fuel cost due to 2.5% increase in efficiency
Net savings : Rs.12,44,000.00 Rs. 11,076.00   Rs. 38,633.00 Rs. 27,556.205,40,000.00 9,135.00   21,600.00 12,465.00

DOSAGE PROCEDURE

ECONOFIX-10 in administered by introducing it into the Furnace while the Boiler or Heater is in operation.
FOR OIL FIRED BOILERS AND HEATERS - MANUAL FIRED :
Switch off burner and remove the Oil needle valve or burner gun. For this operation the burner has to be Shut Off,
for about ten minutes. If the Boiler has multiple Furnaces or Flues. the dosage of ECONOFIX-10 has to be distributed evenly among the furnaces. FOR COAL FIRED BOILERS AND HEATERS - MANUAL FIRED : Wait tor the Flame to die Out after the fresh Coal has been charged and when only embers are glowing, feed ECONOFIX-10 as evenly as possible into the furnace. Shut the furnace doors without feeding coal for about ten minutes. The Boiler or Heater may be fired normally after that. FOR COAL FIRED BIOLERS AND HEATERS - STROKE FIRED : ECONOFIX-10 should be placed into the furnace one third the distance from the coal feeding end. The stoker may be operated normally.